Found: 1771
|
Ferguson | TX9 | Dead - intermittent. | On/off switch ( Lorlin type ) intermittent. | 14-09-04 |
Ferguson | TX9 | Dead - intermittent. | SCR1 ( PC1040 ) | 14-09-04 |
Ferguson | TX9 | Dead - mains fuse blown. | TR62 s/c. | 14-09-04 |
Ferguson | TX9 | Dead - mains fuse gone. | SCR1 s/c W77 s/c. | 14-09-04 |
Ferguson | TX9 | Dead - no 18v rail. | DJ on L103. | 14-09-04 |
Ferguson | TX9 | Dead - no fuse's gone. | TR67 ( T6059V ) s/c located back r/h side. | 14-09-04 |
Ferguson | TX9 | Dead - slight ticking sound. | Low 115v/18v rails , R173 ( 10k ) o/c. | 14-09-04 |
Ferguson | TX9 | Dead - st/by only | No 115v from psu - TDA4600 responsible | 14-09-04 |
Ferguson | TX9 | Dead 1.6A fuse blackened | Chopper BU508A s/c; R165 200k o/c | 14-09-04 |
Ferguson | TX9 | Dead 1.6A fuse blackened | Blows fuse even when mains sw off - mains inductor s/c | 14-09-04 |
|
Ferguson | TX9 | DEAD STUCK IN STBY | REMOVE SCAN PLUG IF SET STARTS SUSPECT COILS OR S CORRECTION CAPACITOR | 14-09-04 |
Ferguson | TX9 | Dead with 1.6A fuse blown | 1R8 dropper o/c; BU508 chopper tr s/c; dry joints pin 1 chopper tfmr | 14-09-04 |
Ferguson | TX9 | Dead with 1.6A fuse blown | Chopper BU508A s/c; R165 300k o/c - L107 was not properly connected to BU508A emitter | 14-09-04 |
Ferguson | TX9 | Dead. | Drys on C136 ( 1.8nf ) | 14-09-04 |
Ferguson | TX9 | Dead. | L64. | 14-09-04 |
Ferguson | TX9 | Display - no channel disp - sound mute LED | Print cracked on remote standby panel , DJ on IC2. | 14-09-04 |
Ferguson | TX9 | Distorted sound on right channel. | TR1227 ( BC413C ) | 14-09-04 |
Ferguson | TX9 | Field collapse | R294 18k in dc feedback network o/c | 14-09-04 |
Ferguson | TX9 | Field non lin | C212 0µ1 | 14-09-04 |
Ferguson | TX9 | Flyback lines green at bottom of screen. | W54 ( BZX79C4V7 ) zener by IC52. | 14-09-04 |
Ferguson | TX9 | Focus out | Focus spark gap | 14-09-04 |
Ferguson | TX9 | Frame - roll after frame IC change. | IC Must use correct frame IC TDA1170S as no vert control. | 14-09-04 |
Ferguson | TX9 | Frame - two inches high. | R268 ( 1.5MR ) in series with height control o/c. | 14-09-04 |
Ferguson | TX9 | Frame collapse. | C206 ( 470nf ) o/c ( volts on pin 1 IC55 high ) | 14-09-04 |
Ferguson | TX9 | Frame roll ( off air ) | C206 from 150nf to 470nf , R277 from 210k to 66.5k. | 14-09-04 |
Ferguson | TX9 | Frame roll when hot. | R277 ( 210k ) high fit 180k , 210k for best lock. | 14-09-04 |
Ferguson | TX9 | FUSE BLOWN , BUT LOPT SCREAMS LOUDLY THEN FUSE BLOW | 1Kohm LINE HOLD RV206 | 14-09-04 |
Ferguson | TX9 | Gain low. | C106 ( 10uf ) leaky ( volts on IC101 P7 to high , 11v ) | 14-09-04 |
Ferguson | TX9 | Grey scale - not correct. | RV67 balance control , chroma delay line , Posistor. | 14-09-04 |
Ferguson | TX9 | Grey scale fault. | C64/5/8 o/c. | 14-09-04 |