Make | Model | Problem | Solution | Date |
| | | |
Found: 4551
|
Philips | 14PV263 | Set produces audible noise in stand-by | Add a small LEBL (leading edge blanking) PCB, to avoid auto oscillation of transformer 5330 (or 5331). A modification letter is included with the LEBL PCB.
This PCB is available with service nr. 4822 214 12173. | 14-09-04 |
Philips | 14PV263 | Spare part information | A repair kit , containing PULLEY SHAFT + WORM SHAFT (POS. 47+48) is delivered with codenumber 4822 310 10657.
This kit can be used for all TURBO- and ECO mechanisms ! | 14-09-04 |
Philips | 14PV263 | Spare part information | If the lever inside the mains-switch is broken, the switch doesn't remain in the "ON" position.
Solution: replace the switch by a new one. Improved switches of a newer production range are on stock. (4822 276 13542) | 14-09-04 |
Philips | 14PV263 | Start up problems | When the set is switched on by the mains-switch while a cassette is in the set, the front LED starts blinking, but the set doesn't start.
Solution:
Check the primary voltage (Ubat) and adjust this for 14" sets to exactly 101.5 Volt. (See chapter 3.1.1 | 14-09-04 |
Philips | 14PV263 | Start up problems after replacing TS7352 | When TS7352 is replaced, it can happen that the set doesn't start up properly.
There are 2 possible solutions for this problem:
- use SGS type MTP3055E (4822 130 63726).
- In case of a motorola type MTP3055V (4822 130 60838), add a 22 uH coil soldered | 14-09-04 |
Philips | 14PV263 | Strange colours after recording. | Check chroma IC7051 (4822 209 90538).
| 14-09-04 |
Philips | 14PV263/01 | Codenumber information - new software | A new software version (PTCP2-7) is available for the control uP (IC 7801). Service codenumber is 4822 209 15271.
This new version is only used in the following sets:
14PV263/01, 14PV162/01, 14PV162/05, 14PV162/07, 14PV163/05, 14PV163/05H, 14PV263/01, | 14-09-04 |
Philips | 14PV263/01 | Option code: 24492 | From week 02/97 onwards the option code is printed on the typesticker. Always use this code !
For early sets without this information on the typesticker, the option code is: 24492 | 14-09-04 |
Philips | 14PV263/02 | New VPS IC SDA5642-6 (pos. 7840) | Since production week 9741 a new VPS IC pos. 7840 (SDA5642-6) is introduced in production. This IC is not compatible with the previous one. When ordering, look at the printing on the IC !
Old: SDA 5642-5 - codenumber 4822 209 32728
New: SDA 5642-6 - co | 14-09-04 |
Philips | 14PV263/02 | Option code: 23532 | From week 02/97 onwards the option code is printed on the typesticker. Always use this code !
For early sets without this information on the typesticker, the option code is: 23532 | 14-09-04 |
|
Philips | 14PV264 | Codenumber information | The codenumber for the spacer between on/off switch and the knob (pos 3) is 4822 402 10702 | 14-09-04 |
Philips | 14PV264 | Key set | The key set assy has been codified for all B-range TVCR's. This will allow to change the keys without having to change the complete frame.Servicenr. 4822 410 11075.
Key set for: 14PV263/01/02/08/13 - 14PV264/39 - 14PV163/05 - 14PV172/01/05/08/13/39 - 14P | 14-09-04 |
Philips | 14PV264 | Modification | From production week 9725, the IC's SDA5649, SDA5649x and SDA5648 are replaced by a SDA5650 (4822 209 15504).
This new IC is fully compatible with the others, but has better characteristics. In addition to this modification, R3812 on the small signal bo | 14-09-04 |
Philips | 14PV264 | Start up problems | When the set is switched on by the mains-switch while a cassette is in the set, the front LED starts blinking, but the set doesn't start.
Solution:
Check the primary voltage (Ubat) and adjust this for 14" sets to exactly 101.5 Volt. (See chapter 3.1.1 | 14-09-04 |
Philips | 14PV264/39 | Codenumber information - new software | A new software version (PTCP2-7) is available for the control uP (IC 7801). Service codenumber is 4822 209 15271.
This new version is only used in the following sets:
14PV263/01, 14PV162/01, 14PV162/05, 14PV162/07, 14PV163/05, 14PV163/05H, 14PV263/01, | 14-09-04 |
Philips | 14PV274 | Calling installation menu | The installation menu is activated by the following procedure:
- switch on the set by means of the stop key.
- Press simutaneously the "stop" key and the "volume -" key on the set. | 14-09-04 |
Philips | 14PV274 | Codenumber correction for deck-up (IC7410) | The codenumber for the deckprocessor was wrong in the first Service Manual (4822 726 15451).
In service information TVCR96-01 and in the new manual the correct codenumber is given.
The codenumber for the deck-up for sets with non-turbo drive is: 4822 2 | 14-09-04 |
Philips | 14PV274 | int. goes to stby on its own | replace T7687 BC547B (line drive emitter follower) | 14-09-04 |
Philips | 14PV274 | Key set | The key set assy has been codified for all B-range TVCR's. This will allow to change the keys without having to change the complete frame. Servicenr. 4822 410 11075.
Key set for: 14PV263/01/02/08/13 - 14PV264/39 - 14PV163/05 - 14PV172/01/05/08/13/39 - 14 | 14-09-04 |
Philips | 14PV274 | Memory erase procedure | The contents of the memory can only be cleared via the service mode. This option is not available for end users. (Risc of destroying option codes).
Service mode: press "STOP" on Remote Control and "PLAY" on the set for 5 seconds. Select the second page | 14-09-04 |
Philips | 14PV274 | Modification | From production week 9725, the IC's SDA5649, SDA5649x and SDA5648 are replaced by a SDA5650 (4822 209 15504). This new IC is fully compatible with the others, but has better characteristics. In addition to this modification, R3812 on the small signal boar | 14-09-04 |
Philips | 14PV274 | Spare part information | If the lever inside the mains-switch is broken, the switch doesn't remain in the "ON" position.
Solution: replace the switch by a new one. Improved switches of a newer production range are on stock. (4822 276 13542) | 14-09-04 |
Philips | 14PV274 | Start up problems | When the set is switched on by the mains-switch while a cassette is in the set, the front LED starts blinking, but the set doesn't start.
Solution:
Check the primary voltage (Ubat) and adjust this for 14" sets to exactly 101.5 Volt. (See chapter 3.1.1 | 14-09-04 |
Philips | 14PV274 | Start up problems after replacing TS7352 | When TS7352 is replaced, it can happen that the set doesn't start up properly.
There are 2 possible solutions for this problem:
- use SGS type MTP3055E (4822 130 63726).
- In case of a motorola type MTP3055V (4822 130 60838), add a 22 uH coil soldered | 14-09-04 |
Philips | 14PV274/39W | Codenumber information - new software | A new software version (PTCP2-7) is available for the control uP (IC 7801). Service codenumber is 4822 209 15271.
This new version is only used in the following sets:
14PV263/01, 14PV162/01, 14PV162/05, 14PV162/07, 14PV163/05, 14PV163/05H, 14PV263/01, | 14-09-04 |
Philips | 14PV274/39W | Key set | The key set assy has been codified for all B-range TVCR's. This will allow to change the keys without having to change the complete frame. Servicenr. 4822 410 11071. | 14-09-04 |
Philips | 14PV284 | To access tuning mode | Press 'STOP' & 'VOL -' together & follow os instructs | 14-09-04 |
Philips | 14PV284 Combi | Some buttons on handset not working | It should be noted that the VCR buttons on the remote can be set to VCR 2 coding although this is not a documented feature. This will result in the VCR part of the Combi not working via remote. Pressing 'STOP' and '2' together on the remote changes the code to VCR 2. Pressing 'STOP' and '1' together on the remote will change the code back to VCR 1. The TV controls are unaffected.Removing the batteries and pressing any button then refitting the batteries will also set the code back to VCR 1.
Note that the remote should be set to VCR1 for the VCR buttons to work the Combi. | 14-09-04 |
Philips | 14PV2841/055 | Remote control works on TV sect only | Hset faulty pt no 4822 219 10593 | 14-09-04 |
Philips | 14PV320 | Dead with 320v on 2SK2750 FET | Replace FET 7300 - used BUZ90AF | 14-09-04 |