Philips | ANUBIS-A | Supply in protection. | Check/replace LOT (L5445; 4822 140 10406) (short circuit between several coils). | 14-09-04 |
Philips | ANUBIS-A | Timer not OK, no 10min/20min etc. | Replace IC7600 by new software version TMP47C834N-R165 (4822 900 10508) | 14-09-04 |
Philips | ANUBIS-A | Totally inoperative. | Check track between pin 1 LOT 5445 and collector of T7445 on interruption. | 14-09-04 |
Philips | ANUBIS-A | Totally inoperative. | Replace line transistor T7445 BUT11AF by BU1508DX (4822 130 63569)
| 14-09-04 |
Philips | ANUBIS-A | Totally saturated colour. | Check/replace delay line IC7221 - TDA4660; 4822 209 63108. | 14-09-04 |
Philips | ANUBIS-A | TXT does not work | Change the value of capacitor C2703 on decoder plate to 56pF (4822 122 31774). | 14-09-04 |
Philips | ANUBIS-A | When switching to stand-by, picture flickers and the red LED blinks | Check/replace Zenerdiode D6568 (LLZ-F6V2; 4822 130 81147).
| 14-09-04 |
Philips | ANUBIS-A | White distorted picture. Noise in sound. TXT wrong characters. | Check/replace IC7015 (TDA4504B; 4822 209 63107).
| 14-09-04 |
Philips | ANUBIS-B | After a while the alarm led is flashing (error 8). | Replace memory IC7685, ST24C02A (4822 209 62098)
| 14-09-04 |
Philips | ANUBIS-B | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV6018
------------------------------------------------------
4822 209 33153
Hotel mode for uC P83C054-CV6018: YES
Hotel TV, so always hotel mode | 14-09-04 |
|
Philips | ANUBIS-B | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV6012
------------------------------------------------------
Replaced by uC P83C054-CV6018; 4822 209 33153
Hotel mode for uC P83C054-CV6012: YES
Hotel TV, so always hotel mode | 14-09-04 |
Philips | ANUBIS-B | ANUBIS-B with uC P83C054-CV6006 | ANUBIS-B with uC P83C054-CV6006
-------------------------------
Replaced by uC P83C054-CV6107; 4822 209 33634
Hotel mode for uC P83C054-CV6006: YES
Hotel mode enabling for uC P83C054-CV6006:
1. Enter the Service Default Mode
2. Enter Service Menu | 14-09-04 |
Philips | ANUBIS-B | ANUBIS-B with uC P83C054-CV6014 | ANUBIS-B with uC P83C054-CV6014
-------------------------------
Replaced by uC P83C054-CV6107; 4822 209 33634
Hotel mode for uC P83C054-CV6014: YES
Hotel mode enabling for uC P83C054-CV6014:
1. Enter the Service Default Mode
2. Enter Service Menu | 14-09-04 |
Philips | ANUBIS-B | ANUBIS-B with uC P83C054-CV6107 | ANUBIS-B with uC P83C054-CV6107
-------------------------------
4822 209 33634
Hotel mode for uC P83C054-CV6107: YES
Hotel mode enabling for uC P83C054-CV6107:
1. Enter the Service Default Mode
2. Enter Service Menu by pressing simultaneously "VOL | 14-09-04 |
Philips | ANUBIS-B | At switching-off, spot on the middle of the screen. | Change capacitor C2470 from 22uF into 4.7uF - 4822 124 80143
| 14-09-04 |
Philips | ANUBIS-B | Auto contrast function not optimal. | Change:
R3614 into 82k (4822 116 52304)
R3633 into 270k (4822 051 10274)
R3657 into 15K (4822 051 10153)
R3681 into 30K (4822 116 52267)
R3685 into 6k8 (4822 051 10682).
REMARKS :
Introduced in production in week 9242.
| 14-09-04 |
Philips | ANUBIS-B | Bad picture. Picture out of focus. | Leak current in CRT socket. Replace CRT socket (4822 255 70251).
| 14-09-04 |
Philips | ANUBIS-B | Colours disappears. | Check capacitor C2269 (22nF; 4822 126 11544) on the mains PCB.
| 14-09-04 |
Philips | ANUBIS-B | Correction to service manual | Correction to service manual
----------------------------
In the spare parts list of service manual ANUBIS B AA two part
numbers are quoted for the line output transformer and also for the
line linearity coil. The component used depends on the picture
tu | 14-09-04 |
Philips | ANUBIS-B | Drift of varicap voltage. | Delete C2606.
REMARKS :
Introduced in production from production code PM009223 or higher.
| 14-09-04 |
Philips | ANUBIS-B | Error codes | Error codes
-----------
The error codes for the Anubis B Hotel TV (xxHTxxxx/xx) is not
published yet:
For the total overview herewith a table is given for both the normal
Anubis B and the Anubis B Hotel:
Error LED Anubis B An | 14-09-04 |
Philips | ANUBIS-B | From stand-by, by pressing "program -/+", "E3" will be shown | Change the value of C2560 to 1000 uF (4822 124 40214). Change the
value of R3452 to 1 Ohm (4822 052 10108). Change the value of R3782
to 18 Ohm (4822 053 10189).
| 14-09-04 |
Philips | ANUBIS-B | Horizontal black stripe | Distorted saw-tooth signal at input vertical amplifier.
Check C2413 10nF (4822 122 32442).
| 14-09-04 |
Philips | ANUBIS-B | Horizontal white line at the top side. | Vertical deflection fault, bad contact R3415 (820R 4822 053 11821).
| 14-09-04 |
Philips | ANUBIS-B | Hotel mode feature | Hotel mode feature
------------------
The software of the ANUBIS B is provided with the "Hotel" mode
feature. To activate this feature proceed as follows:
1) With the receiver switched off at the mains switch,
interconnect pins M61 and M62 (adjacen | 14-09-04 |
Philips | ANUBIS-B | How to activate "Hotel mode" | Identification on uP: CV6006
Hotel Mode activation:
---------------------
First enabling, activate hotel mode option in Service Menu via
OPTION 2 menu. Then select program 38. Then press simultaneously
"INSTALL" and "PROG+" on local keyboard (OSD "38" fr | 14-09-04 |
Philips | ANUBIS-B | How to activate "Hotel mode" | Identification on uP: CV6014/CV6107/107
Hotel Mode activation:
---------------------
See CV6006, but now first press "INSTALL" on the local keyboard,
the press "SLEEPTIMER" on the remote control while keep pressing
"INSTALL" on the local keyboard for at | 14-09-04 |
Philips | ANUBIS-B | How to activate "Hotel mode" | Applicable for family: Hotel TV
Identification on uP: CV6012/CV6018/CV6109/109
For AB sets
Hotel Mode activation:
---------------------
Dedicated Hotel TV set, so always hotel mode.
Specification of the Hotel mode:
-------------------------------
See re | 14-09-04 |
Philips | ANUBIS-B | How to de-activate "Hotel mode" | Identification on uP: CV6006
Hotel Mode de-activation:
------------------------
Select program 38. Then press simultaneously "INSTALL" and
"PROG+" on local keyboard (OSD "38" from red to green). Put the
set in stand-by and then switch on via PROG+/-.
For | 14-09-04 |
Philips | ANUBIS-B | How to de-activate "Hotel mode" | Identification on uP: CV6014/CV6107/107
Hotel Mode de-activation:
------------------------
See CV6006, but now first press "INSTALL" on the local keyboard,
then press "SLEEPTIMER" on the remote control while keep pressing
"INSTALL" on the local keyboard | 14-09-04 |