Make | Model | Problem | Solution | Date |
| | | |
Found: 4551
|
Philips | K40 | No tuning/chan display aft LOPTx replacement | Diode 6102 leaky & 3132 2R7 fusible o/c | 14-09-04 |
Philips | K40 | NO VIS , LOUD TRUMPETING | D6154 BY229 | 14-09-04 |
Philips | K40 | POOR COL FROM COLD | C2164 2.2mfd , 63v NEAR TDA3561 | 14-09-04 |
Philips | K40 | Raster - blue with flyback lines. | C2216 leaky. | 14-09-04 |
Philips | K40 | SLOW STARTER | C2128 100MFD ( S.MODE SERIES CAP. ) | 14-09-04 |
Philips | K40 | Snowy screen - no tuning volts | R3104 18k on main pcb | 14-09-04 |
Philips | K40 | Sound - no sound - EHT cap leaking. | IC7202 ( HEF4052 ) on power/scart board. | 14-09-04 |
Philips | K40 | Sound - no sound or picture. | Dry joints on L5157 leave on for few hours TDA3576. | 14-09-04 |
Philips | K40 | Squealing - no go. | R3192 ( 680R , 1w ) on PCB under CRT neck. | 14-09-04 |
Philips | K40 | St/by only - hiss from spkr | red lead from psu cracked internally | 14-09-04 |
|
Philips | K40 | St/by only - no line drive | IC TDA3576B; R3192 680R o/c | 14-09-04 |
Philips | K40 | Striations on left-hand side. | Check R3191 for o/c. | 14-09-04 |
Philips | K40 | Txt lines at top of pic | C2107 100µ | 14-09-04 |
Philips | K40 | Txt lines showing at top of pic | C2107 100µ 50v | 14-09-04 |
Philips | K40 | VERY FAINT RASTER | CHECK THE TDA3561 COLOUR IC | 14-09-04 |
Philips | K40 | WHISTLING | BU508 SHORT CHECK IC7120 OPTO ( CNX62 ) | 14-09-04 |
Philips | K40 Chassis 26CS4895-02R | Sound low and distorted | C/R TDA 2545 IC in IF module. | 14-09-04 |
Philips | KT3 | 155v rail low. | DJ on R1583 ( 2R2 ) | 14-09-04 |
Philips | KT3 | Blank raster with flyback lines | R455 SC 560R 1W. | 14-09-04 |
Philips | KT3 | Blank raster with flyback lines. | R587 ( 100R ) by drive pre-sets change in value 160v feed to RGB | 14-09-04 |
Philips | KT3 | Blank raster. | IC TDA2571 sync/line IC. | 14-09-04 |
Philips | KT3 | Brightness - intermittent. | Drys on plug by high wattage res on remote PCB. | 14-09-04 |
Philips | KT3 | Channel change - intermittent. | IC70 ( 4074 ) | 14-09-04 |
Philips | KT3 | col fades out after 2 hrs | C56 0.1µ connected to pin 23 TDA3560 faulty | 14-09-04 |
Philips | KT3 | Continous trip | Dry joints C567 (below LOPTx) | 14-09-04 |
Philips | KT3 | CRT down. | For tube boost s/c 1 of the chokes L9603/9604 Note only do 1. | 14-09-04 |
Philips | KT3 | Dead. | 4.7R w/w R6191 may be shown as R6291 | 14-09-04 |
Philips | KT3 | Dead. | Tripler , BU205. | 14-09-04 |
Philips | KT3 | Dead. | 4.7R , mains recys , D454 , D455 ( BAS11 ) by LOPTX. | 14-09-04 |
Philips | KT3 | Dead. | T7336. | 14-09-04 |