Make | Model | Problem | Solution | Date |
| | | |
Found: 4551
|
Philips | FL1.2 | Spook in picture | Use special antenna cables.
Codenumbers:
4822 321 61224 PAL 1 meter
4822 321 61225 PAL 2 meter
4822 321 61226 SECAM 1 meter
4822 321 61227 SECAM 2 meter
| 14-09-04 |
Philips | FL1.2 | Stripes in picture in 36" sets | The following production change has been introduced to reduce
stripes in receivers with serial numbers AG039143 or higher.
1) Apply a shorting link between pins 15 and 16 of LOT (5555).
2) Cut away the earth lead between connectors S03 and L03 (pin 1 | 14-09-04 |
Philips | FL1.2 | Synchronization, picture disappears | D6703 and T7704 defective on picture tube panel.
| 14-09-04 |
Philips | FL1.2 | The +141 is about 110V instead of 141V | It is recommended to replace the SOPS PWB (4822 212 23755).
| 14-09-04 |
Philips | FL1.2 | Ticking noise and line in picture | Transistor 7381 (BC848C; 5322 130 42136) defective when hot.
| 14-09-04 |
Philips | FL1.2 | Total inoperative, leds blinking, error 99 | Check and replace if necessary C2504 and/or 2505 (2kV HRR) on the
Large signal panel.
Replace by a 3kV15 HR-R capacitor if possible:
820pF 4822 126 13152
1nF 4822 126 13153
1,2nF 4822 126 13154
1,5nF 4822 126 13155
1,8nF 4822 126 13156
2, | 14-09-04 |
Philips | FL1.2 | Totally inoperative. | Transistors 7250 (BUX85F; 4822 130 62509) and
7251 (BC848; 4822 130 61207) in microSOPS defective.
Or D6251 (LLZ-C5V6; 4822 130 80954) and
R1250 (=R3230; 1 Ohm; 4822 052 10108) defective.
Or T7270 (BD825; 4822 130 41746)
Or T7201 (BC857C; 5322 130 427 | 14-09-04 |
Philips | FL1.2 | Tuning does not function | Resistor R3240 on LSP in V-tuning wire broken.
| 14-09-04 |
Philips | FL1.2 | Unstable picture, horizontal jitter. | Check/replace R3405 on the LSP. (4822 051 10303 for 50 Hz sets;
4822 051 10333 for 100 Hz sets).
| 14-09-04 |
Philips | FL1.2 | With fast moving picture poor picture quality (scan effect visible) | Change software into version V52 or higher 4822 900 10337.
REMARKS :
With this software it is possible to switch off LFR.
| 14-09-04 |
|
Philips | FL1.2 | Wrong service batch of ST24C08CB1 memory IC's 4822 | Wrong service batch of ST24C08CB1 memory IC's 4822 209 32283
------------------------------------------------------------
Temporarily a wrong batch of EAROM's has been delivered, causing the
fault "NVM MEMORY NOT WRITE PROTECTED" after replacing the EAROM | 14-09-04 |
Philips | FL1.2 | Wrong synchronization, unstable colors | D6417 on the LSP dependent on temperature, check/replace
(4822 130 81223)
| 14-09-04 |
Philips | FL1.2 28ML8762/05B | Fails to start with error code "99" | Try changing chopper Tr to 2SC3973B (BUT11AF) | 14-09-04 |
Philips | FL1.2 28ML8762/05B | Narrow pic & goes off | 9n1 tuning cap in psu | 14-09-04 |
Philips | FL1.2-AB | Bad focus or focus varies in a new set or after CRT replacement | Possible solution:
Short circuit the focus and the G2 pins of the picture tube with the
aquadag coating. Switch the set on for approximately 5 seconds.
After this return the set to its original condition. Check if the
focus adjusted normally. If not repla | 14-09-04 |
Philips | FL1.2-AB | Correction to service information FL 95.01 | Correction to service information FL 95.01
------------------------------------------
Correction in the overview of 100Hz and Proscan boxen.
The replacement for service code 4822 212 30534 must be 4822 212 31231
The replacement for service code 4822 21 | 14-09-04 |
Philips | FL1.2-AB | Low Brightness TXT and OSD, Picture OK | If this condition occurs, check the Option Codes.
Resetting the Option Code numbers as per the Service Manual provided
the cure.
| 14-09-04 |
Philips | FL1.2-AB | Overview of SOPS repair kits | Overview of SOPS repair kits
----------------------------
FL1.0 AG00 upto AG03 4822 310 20492
FL1.0 AG04 and higher 4822 310 31921
FL1.0S 4822 310 31924
FL1.1 25" and 28" 4822 310 31919
FL1.1 33" 4822 310 31932
FL1.1S | 14-09-04 |
Philips | FL1.2-AB | Picture twists from top | Voltage of pin 8-IC7450 (TDA3654Q) on the LSP has raised to ca. 20 V.
Check diode 6451 (BZX79/C3V6; 5322 130 34834 or
BZX79/C10; 4822 130 61219)
| 14-09-04 |
Philips | FL1.20 | Bad focus or focus varies in a new set or after CRT replacement | Possible solution:
Short circuit the focus and the G2 pins of the picture tube with the
aquadag coating. Switch the set on for approximately 5 seconds.
After this return the set to its original condition. Check if the
focus adjusted normally. If not repla | 14-09-04 |
Philips | FL1.20 | Bad pict. No menu. Dark bars over pict. Red pict. in dig.scan mode. | +5V was 4,3V instead of 5,1V.
IC7551 (LM358N 4822 209 70672) defective.
IC7209 (SAA7158 4822 209 31059) Bendic defective.
| 14-09-04 |
Philips | FL1.20 | Bad picture. Picture scrolls. No RC reaction. | +5V was 4,1V instead of 5,1V. Replace IC7551 (LM358N; 4822 209 70672)
| 14-09-04 |
Philips | FL1.20 | Blank picture. OSD not synchronised and too large, no TXT. | Check/replace memory IC 7900 (ST24C08CB1; 4822 209 32283).
| 14-09-04 |
Philips | FL1.20 | Both languages can be heard by Dual Nicam signals | For FL1-PTV change the software into V89; 4822 900 10732
For all other FL sets change the software into V88; 4822 900 10723
REMARKS :Introduced in production from week 9614 onwards. | 14-09-04 |
Philips | FL1.20 | Correction to Product Survey 1996-4 | Correction to Product Survey 1996-4 (4822 727 21505)
----------------------------------------------------
On page PCS 41989 is mentioned at:
FL1.10 AG11 and higher: Control panel 4822 212 31708
FL1.17 AG20 : Control panel 4822 212 31708
FL | 14-09-04 |
Philips | FL1.20 | Correction to service information FL 95.01 | Correction to service information FL 95.01
------------------------------------------
Correction in the overview of 100Hz and Proscan boxen.
The replacement for service code 4822 212 30534 must be 4822 212 31231
The replacement for service code 4822 21 | 14-09-04 |
Philips | FL1.20 | Dark picture, only green led, no menu or OSD. | +5V supply was 4,1V. Voltage D6551 was 4,3V instead of 5,6V.
Check/replace D6551 (4822 130 80954).
| 14-09-04 |
Philips | FL1.20 | Four dark bars over the picture. | The +5 volt was 5.6 volt instead of 5.1 volt.
Check/replace IC7551 (4822 209 70672).
| 14-09-04 |
Philips | FL1.20 | Low Brightness TXT and OSD, Picture OK | If this condition occurs, check the Option Codes.
Resetting the Option Code numbers as per the Service Manual provided
the cure.
| 14-09-04 |
Philips | FL1.20 | Noise on high volume | Perform the following modifications on the SSP:
Add on position 3618 4,7nF (4822 122 31784)
Add on position 3619 jumper (4822 051 10008)
Connected in series from 2604/4610 to earth.
Change position 4610 into 1k ohm (4822 051 10102) | 14-09-04 |