Make | Model | Problem | Solution | Date |
| | | |
Found: 4551
|
Philips | 14PV330 | Dead | D6391 BYW98/200 in psu s/c | 14-09-04 |
Philips | 14PV345/05 TVCR99 | Dead at start up with Rec LED flashing | Sus EEPROM IC7818 on video board | 14-09-04 |
Philips | 14PV345/05 TVCR99 | No pic TV or Pback - sound, OSD & Txt ok | Painter IC SAA5562 was not sending correct info to TDA8841 jungle chip pin 26 - SAA chip faulty | 14-09-04 |
Philips | 14PV461 | Codenumber information | The codenumber for the spacer between on/off switch and the knob (pos 3) is 4822 402 10702 | 14-09-04 |
Philips | 14RGR1 | Removing Hotel Mode | press control + & - on ch38 | 14-09-04 |
Philips | 14TV240/05 | No pic - sound ok | HT correct, no line drive; 3584 47R o/c | 14-09-04 |
Philips | 14TV240/05 | Pic missing - sound ok | No line dr - Q7584 BC637-16 o/c or R3584 47R o/c or D6581 (use 1N4148) leaky | 14-09-04 |
Philips | 14TVCR240 | Codenumber correction | The codenumber (4835 310 57339) in the Service Manual (see page 1-2-19) for the extension PCB of the mechanism, is wrong.The correct codenumber is 4822 321 62609. | 14-09-04 |
Philips | 14TVCR240 | Codenumber information | A new software version (PTCP2-7) is available for the control uP (IC 7801). Service codenumber is 4822 209 15271.
This new version is only used in the following sets:
14PV263/01, 14PV162/01, 14PV162/05, 14PV162/07, 14PV163/05, 14PV163/05H, 14PV263/01, | 14-09-04 |
Philips | 14TVCR240 | Correction partslist | In the partslist, 17.734 MHz is mentioned for X-tal pos.1200. This has to be 4.43 MHz. The codenumber 4822 242 81809 is correct. Also the specifications of the X-tal on the circuit diagramm on page 1-3-7 is correct. | 14-09-04 |
|
Philips | 14TVCR240 | Damages tapes; eject of cassette with difficulty. | Replace kit I (4822 310 31963).
| 14-09-04 |
Philips | 14TVCR240 | Dead | Check start up volts pin 6 TDA4605 should be 10v; if low at 3v check UG06B diode D6334 for leak (pt no 4822 130 83307) | 14-09-04 |
Philips | 14TVCR240 | Dead | D6581 - used By133 in lieu | 14-09-04 |
Philips | 14TVCR240 | Dead with blurting noise | LOPTx s/c CHS code no P81397 | 14-09-04 |
Philips | 14TVCR240 | dead, PSU not running | D6334 UG06B leaky (482213083307) | 14-09-04 |
Philips | 14TVCR240 | Field collapse | TDA3653 replaced | 14-09-04 |
Philips | 14TVCR240 | How to erase memory | Press simultanuously buttons REWIND, WIND and PROGRAMM (<<, >> and P-) while switching on the power supply.
Note: Correct your service manual on page 1-1-11.
The description in the Instruction For Use is correct. | 14-09-04 |
Philips | 14TVCR240 | Key set | The key set assy has been codified for all B-range TVCR's. This will allow to change the keys without having to change the complete frame. Servicenr. 4822 410 11069.
Key set for: 14PV162/01/02/05/07/08/13/58 - 14PV170/05 - 14TVCR240/01N. | 14-09-04 |
Philips | 14TVCR240 | Memory erase procedure | The contents of the memory can only be cleared via the service mode. This option is not available for end users. (Risc of destroying option codes).
Service mode: press "STOP" on Remote Control and "PLAY" on the set for 5 seconds. Select the second page | 14-09-04 |
Philips | 14TVCR240 | Modification picture tube | From production week 9610 onwards, an ORION picture tube was mounted. The codenumber was 4822 131 11075.
Together with this picture tube capacitor C2586 has been changed to 8 nF - 1600 V. Codenumber 4822 121 70629.
For replacement ORION picture tube by | 14-09-04 |
Philips | 14TVCR240 | Motor holder with reverse prism included | Cut part from the motor holder.
REMARKS : For drawing see repair information PAL 96/09 (from 13.10.96) | 14-09-04 |
Philips | 14TVCR240 | No pic - sound ok | R8511 o/c; IC7510 TDA3653B f o/p chip u/s | 14-09-04 |
Philips | 14TVCR240 | No picture, but sound is OK. | Check the +25V supply. If this is not present, check resistor R3511. This resistor is mounted on the supply-PCB near the LOT. This resistor is specified by correct type only, as mentioned in the service manual.
12NC: 4822 052 11278 (2E70.5W safety). | 14-09-04 |
Philips | 14TVCR240 | No picture, sound OK | Check R3511 for interruption. This resistor can be found behind the line transformer, on the power PCB, in the +25 V supply circuit.
Note: Do not use any resistor, but use exclusively codenumber 4822 052 11278 (2,7E - 0.5 Watt), because of its specific p | 14-09-04 |
Philips | 14TVCR240 | No vertical deflection. | Replace resistor R2511 (2.7 Ohms / 4822 050 22708). | 14-09-04 |
Philips | 14TVCR240 | Preventive tip | If FET 7352 is found to be defective, it is advised to mount a 15 V zenerdiode (BZX79-C15) between the drain and the gate. Mount cathode to gate and anode to drain.
Codenumbers:
FET 7352 : 4822 130 60838.
ZENER (BZX79-C15): 4822 130 34281.
Introd | 14-09-04 |
Philips | 14TVCR240 | Service hint | On certain TVCR sets sent to the Eastern European Countries, the VPS function cannot be activated via the remote control. Inside the remote control, a jumper is connected to pin 10 of the IC instead of being connected to pin 11:
- when the jumper is on p | 14-09-04 |
Philips | 14TVCR240 | Service Manual information | Deviations between 14TVCR240/01 and 14TVCR240/01N:
For 14TVCR240/01N, use The Service Manual of 14PV162/01.
Additional codenumbers:
position description codenumber
1 Frame assy 4822 464 51055
1/5 Lift | 14-09-04 |
Philips | 14TVCR240 | Set produces audible noise in stand-by | Add a small LEBL (leading edge blanking) PCB, to avoid auto oscillation of transformer 5330 (or 5331). A modification letter is included with the LEBL PCB.
This PCB is available with service nr. 4822 214 12173. | 14-09-04 |
Philips | 14TVCR240 | Set produces audible noise in stand-by | Add a small LEBL (leading edge blanking) PCB, to avoid auto oscillation of transformer 5330 (or 5331). A modification letter is included with the lable PCB. This PCB is available with service nr. 4822 214 12173.
Since production week 9723 this circuit is | 14-09-04 |