Philips | MD1.1E | Dead with mains fuse blown & chopper Tr s/c | Arcing positor caused it | 14-09-04 |
Philips | MD1.1E | Easy way to check the Power Supply | Easy way to check the Power Supply----------------------------------
The MC44603 can be checked for basic operation without the set being connected to the Mains supply.
Method:
1) Discharge the 300V smoothing Capacitor.
2) Connect a BYD33D Diode to | 14-09-04 |
Philips | MD1.1E | Error in Product Survey 1997-3 | Error in Product Survey 1997-3
28PT5001/02B is incorrectly referred to as styling 149.
The correct styling for 28PT5001/02B is styling 103.
This styling is published in Styling Yearbook 1996-4 (4822 727 21505) | 14-09-04 |
Philips | MD1.1E | Errors in characters with GERMAN or TURKISH teletext | Replace the uP by one of the following uPs:
VERSION...LANGUAGES...SERVICE CODE NUMBER
M12BA1-4.0...F-D-NL-I...4822 900 10988
succ. of uPs with idents 3161, 3199, 3229 and uP SV02-M11C1-43
M12BA2-4.0...SW-DK-N-FI...4822 900 10984
successor of uPs w | 14-09-04 |
Philips | MD1.1E | Errors with characters in German Teletext | Replace the microprocessor by version MID15-3.9 (ident 3259)
The service code of this microprocessor is 4822 209 13579.
REMARKS :THIS SOLUTION IS NOT VALID FOR TURKEY!!! IN TURKEY uP MID15-3.9
CANNOT BE USED. | 14-09-04 |
Philips | MD1.1E | excessive height | replace SMD C2137 with 22pF (532212614103) | 14-09-04 |
Philips | MD1.1E | Faulty colour areas | Check and replace if necessary PTC 3506; 4822 117 12027
| 14-09-04 |
Philips | MD1.1E | Flyback lines across top third of pic | Tr7400 BC327A on Tesla panel - next to fop heatsink | 14-09-04 |
Philips | MD1.1E | Flyback lines visible or no picture at all | FLYBACK LINES
Check and replace if necessary the following components on the
Tesla module (On LSP panel, near supply for the frame deflection):
C2400 22uF 4822 124 41596
D6400 BAV21 4822 130 30842
When there is no picture at all, also c | 14-09-04 |
Philips | MD1.1E | Green picture with flyback lines and then set switches off. | 1. Voltage on cathode green was 30V due to T7342 (BF423; 4822 130 41646) leakage.
2. Check and replace if necessary diode D6304 (BAV21) on picture tube panel (4822 130 30842) | 14-09-04 |
|
Philips | MD1.1E | Horizontal bars or blue picture with SECAM transcoding in PAL program | Short-circuit R3193 on the SSP-panel
REMARKS :introduced in production from week 9533 onwards for /01 sets | 14-09-04 |
Philips | MD1.1E | How to enable/disable "Child Lock" | Press "MENU" button on Remote Control. When the menu appears on the screen, you select "FEATURES" (this expression is language dependent) Within "FEATURES", the "CHILD LOCK" can be enabled or disabled. | 14-09-04 |
Philips | MD1.1E | Hum in sound. | Check and remount cable L28/S28 on the LSP/Audio module.
| 14-09-04 |
Philips | MD1.1E | Incorrect blanking, right side is partly black. | Check and replace if necessary T7403 (5322 130 41982) on the 16:9 module. | 14-09-04 |
Philips | MD1.1E | Interference in picture on 182, 217, 238 and 495 MHz | 1. Use high quality antenna cables and connectors (in case of insufficient result, apply solution 2)
2. Add 3 SMD capacitors (parallel) on pos 2391 audio-module.
470pF; 5322 122 32268
220pF; 4822 122 31173 and
1,5pf; 5322.126.10225
| 14-09-04 |
Philips | MD1.1E | Intermittent coloured lines in picture. | Check and replace if necessary IC7140 (TDA 4665; 4822 209 12635)
| 14-09-04 |
Philips | MD1.1E | Intermittent flicker in picture | Check and replace if necessary zenerdiode 6360 (BZV86-2V0; 4822 130 81424) | 14-09-04 |
Philips | MD1.1E | Intermittent no audio | Check pin 12 of connector I46 on the Audio Module (SCL line). Look for a badly soldered (oxidated) pin 12. Resolder pin 12 if required. | 14-09-04 |
Philips | MD1.1E | Intermittent no colour and picture shifts to one side | The fault was caused by the Chroma X-tal pos. nr. 1117 (4822 242 81809).
The 4.43 Mhz X-tal in these sets is used within the Bimos I.C
(TDA 8366) to provide a internal ref for the Horizontal and Vertical count circuits. | 14-09-04 |
Philips | MD1.1E | Intermittent no picture | Check pin 12 of connector I46 on the Audio Module (SCL line). Look for a badly soldered (oxidated) pin 12. Resolder pin 12 if required. | 14-09-04 |
Philips | MD1.1E | Intermittent no picture and/or sound | Check pin 12 of connector I46 on the Audio Module (SCL line). Look for a badly soldered (oxidated) pin 12. Resolder pin 12 if required. | 14-09-04 |
Philips | MD1.1E | MD1.1E LOT SURVEY for AA SETS | MD1.1E LOT SURVEY for AA SETS
--------------------------------
CRT TYPE SERVICE CODE LOT REMARKS
21" 4822 140 10526 *)
25"BM 4822 140 10528 *)
| 14-09-04 |
Philips | MD1.1E | Modification | Modification
From AG/QG06 onwards a new version of the BiMOS is used in all MD1.1E AA sets;
TDA8366/N3 is replaced by TDA8366/N4.
Therefore a number of components on the SSP has changed.
In ALL MD1.1E AA sets:
item 1117 becomes 4822 242 10692 4.4 | 14-09-04 |
Philips | MD1.1E | Modification | Modification
A new Nicam L panel is introduced in the MD1.2E chassis. It will also be used in the MD1.1E chassis. It is fully compatible with the original panel. The service code of the new Nicam L panel is :4822 212 10919.
REMARKS :The lay | 14-09-04 |
Philips | MD1.1E | MODIFICATION SM MD1.1E in diversity table A2 | MODIFICATION SM MD1.1E in diversity table A2 on page 15
-------------------------------------------------------
Diversity table A2 on page 15 of the SM MD1.1E AA is modified:
Position 7420, column CRT04 (25/28"BM) and CRT05 (21"BM) must be BU2506DF (48 | 14-09-04 |
Philips | MD1.1E | Moire in picture on certain channels (Ch6, Ch11, Ch24 and S12) | Depending on the severity of the problem, a 3 phase solution is available.
If the problem is not sufficiently solved by step 1, continue with 2, etc.
1. Use a high quality antenna cable
2. Add 3 SMD capacitors (in parallel) on position 2391 (Audio Mo | 14-09-04 |
Philips | MD1.1E | No colour on off-air signals or via the scart inputs. | C2143 sm 100nf leaky | 14-09-04 |
Philips | MD1.1E | No colour on off-air signals
or via the scart inputs. Teletext normal.
| Chip capacitor C2143 (100nF) was found to have an 82R leak which was dragging down the supply to pin 1 of the TDA4665 (IC7140) from 4v9 to 1v6. This stopped the chip from outputting the delayed R-Y & B-Y signals. A ceramic alternative mounted on the print side of the board restored normal pictures.
| 14-09-04 |
Philips | MD1.1E | No colour or no colour after some time | Check C2161 (via 3164 on pin 34 IC7119/TDA8366) whether voltage on pt 34 is much lower than 4.5V. Probably C2161 has leakage.
Codenumber C2161 (100 nF 10% 125V) is 4822 126 13161. | 14-09-04 |
Philips | MD1.1E | No colour, OSD and TXT OK. | Check and replace if necessary item C2143 (100nF; 25V; 4822 126 13161)on the SSP. | 14-09-04 |