Make | Model | Problem | Solution | Date |
| | | |
Found: 4551
|
Philips | ANUBIS-A | 50 Hz humm at loudspeakers in stand-by | In case of a 50 Hz humm at the loudspeaker in stand-by of a 3W Anubis A set, it is recommended to replace:
SOPS transformer 4822 148 60299 (dedicated for 3W Anubis A sets) at itemnumber 5525.
REMARKS: The ripple of the +13 supply voltage coming from the | 14-09-04 |
Philips | ANUBIS-A | AFC control is slowly. Station unstable. | Check tuner (UV917/IEC; 4822 210 10405).
| 14-09-04 |
Philips | ANUBIS-A | After a while no picture. Only sound. TXT and OSD are OK. | Check whether DC voltage pin 11 IC7280 (TDA3504) is 3V.
If not, check/replace C2255 (100nF; 4822 122 33496). | 14-09-04 |
Philips | ANUBIS-A | All LEDs in display blinking. | Check LOT 5445 (4822 140 10406).
| 14-09-04 |
Philips | ANUBIS-A | Anubis A option diode for 4 page TXT | Anubis A option diode for 4 page TXT
ONLY FOR ANUBIS A AC
In service information SI94.01 4822 727 20292 the text indication at option diode 6606 is wrong; it should be 4 page TXT.
So the option diodes for Anubis A AC with latest software version R165 | 14-09-04 |
Philips | ANUBIS-A | ANUBIS-A TXT with 3 local controls with uC TMP47C4 | ANUBIS-A TXT with 3 local controls with uC TMP47C434N-R133 (ANUBIS-A AC)
Replaced by uC TMP47C434N-R165; 4822 209 33275
Hotel mode for uC TMP47C434N-R133: YES
Hotel mode activation for uC TMP47C434N-R133: 1.Select program 38 2.Press simultaneously "ME | 14-09-04 |
Philips | ANUBIS-A | ANUBIS-A TXT with 3 local controls with uC TMP47C4 | ANUBIS-A TXT with 3 local controls with uC TMP47C434N-R131 (ANUBIS-AAC) Replaced by uC TMP47C434N-R165; 4822 209 33275
Hotel mode for uC TMP47C434N-R131:YES
Hotel mode activation for uC TMP47C434N-R131:
1.Select program 38 2.Press simultaneously "ME | 14-09-04 |
Philips | ANUBIS-A | ANUBIS-A with 3 local controls with uC TMP47C434N- | ANUBIS-A with 3 local controls with uC TMP47C434N-3144 Replaced by uC TMP47C434N-3146; 4822 209 32117
Hotel mode for uC TMP47C434N-3144: | 14-09-04 |
Philips | ANUBIS-A | ANUBIS-A with 3 local controls with uC TMP47C434N- | ANUBIS-A with 3 local controls with uC TMP47C434N-3145 Replaced by uC TMP47C434N-3146; 4822 209 32117
Hotel mode for uC TMP47C434N-3145: | 14-09-04 |
Philips | ANUBIS-A | ANUBIS-A with 8 local controls with uC TMP47C434N- | ANUBIS-A with 8 local controls with uC TMP47C434N-3123. Replaced by uC TMP47C434N-R217; 4822 209 32171
Hotel mode for uC TMP47C434N-3123: | 14-09-04 |
|
Philips | ANUBIS-A | ANUBIS-A with 8 local controls with uC TMP47C434N- | ANUBIS-A with 8 local controls with uC TMP47C434N-R217 4822 209 32171
Hotel mode for uC TMP47C434N-R217: YES
Hotel mode activation for uC TMP47C434N-R217: 1.Select program 38 2.Press simultaneously "INSTALL" on local keyboard and "SLEEPTIMER" on | 14-09-04 |
Philips | ANUBIS-A | Bad tuning in SECAM L Accent (VHF CH: 47.75). | Change R3604 into 33 ohm (4822 051 10339).
REMARKS: Introduced in production for factory code PM059125, ZB049138 and higher. | 14-09-04 |
Philips | ANUBIS-A | Blinking led. Supply in protection. | Check LOT 5445 (4822 140 10406)
| 14-09-04 |
Philips | ANUBIS-A | Bright picture, fly-back lines | Check/replace LOT 5445 (4822 140 10406)
| 14-09-04 |
Philips | ANUBIS-A | Cannot switch off Hotel Mode after replacement of the micro processor. | For the new software version of the micro processor it is required to switch off the hotel mode feature with the aid of the remote control. However the non remote control set cannot receive the RC signals.Two possible solutions:
1) Make use of an tempora | 14-09-04 |
Philips | ANUBIS-A | Chroma flickering with play-back of copy protected tapes. | On the sync part:
change C 2350 into 47 nF 4822 122 32542
change C 2351 into 4,7 uF 4822 124 40246
change R 3350 into 75 kOhm 4822 051 10753
change R 3351 into 1,5 kOhm 4822 116 52243
On the Chroma part:
add a capacitor of 47 nF (4822 121 43526) | 14-09-04 |
Philips | ANUBIS-A | Codenumber information | Codenumber information. In Service Manual Anubis A AB a wrong code is published for the UV915E/IEC tuner.
The codenumber for the UV915E/IEC should be 4822 210 10448
REMARKS: PS. The codenumber for the UV915E/IEC tuner is correctly published in the Anubi | 14-09-04 |
Philips | ANUBIS-A | Color missing due to wrong color identification of TDA4510. | Add capacitor 2321 27pF (4822 122 31825) between pen 15-IC7250 and mass.
Add capacitor 2310 100nF (4822 122 33496) mounted instead of wire 9268.
REMARKS : Introduced in production for factory code PM059141, ZB069148 and higher. | 14-09-04 |
Philips | ANUBIS-A | Correction on service information SI 94.01 | Correction on service information SI 94.01 (4822 727 20292) In the spare parts list of the issue "play back of copy protected VCR tapes" 2 mistakes are made:
1. R3306 should be 0 ohm jumper (4822 051 10008), not 3k3
2. C2253 should be 1uF (4822 121 5131 | 14-09-04 |
Philips | ANUBIS-A | Corrections on Product survey 1993 Yearbook: | Corrections on Product survey 1993 Yearbook: Styling 13: - missing code number for the external antenne is 4822 303 30435 | 14-09-04 |
Philips | ANUBIS-A | CRT types | CRT types
Some receivers were fitted with a CRT type A34JFQ40X04 in production.The standardized replacement for all 14" receivers with these chassis is the A34EAC01X45. Spacers may have been used when mounting the A34JFQ40X04 in the cabinet. These shou | 14-09-04 |
Philips | ANUBIS-A | Dark yellow picture. | Check connector L3 (picture tube panel).
| 14-09-04 |
Philips | ANUBIS-A | Different TXT panels and IC's | Different TXT panels and IC's. Only for TXT versions
IC 7702, on the TXT panel, and the components around it are only used in: 4 page TXT versions (IC7702 = 4822 209 31069, PCF84C81AP/098) 1 page TXT version with Spanish characters (IC 7702 = 4822 209 32 | 14-09-04 |
Philips | ANUBIS-A | Does not lock several stations. (AFC is too slow) | Check/replace and adjust IF detection coil L5040 (4822 157 63064).
| 14-09-04 |
Philips | ANUBIS-A | Flap front does not lock. | Replace door lock pos.7 (4822 278 10088).
| 14-09-04 |
Philips | ANUBIS-A | Horizontal linearity not optimal. | Change C2450 into 560nF (4822 121 42442).
REMARKS :Introduced in production for factory code: PM079220 and higher. | 14-09-04 |
Philips | ANUBIS-A | Horizontal width/linearity not correct. | Replace C2450. | 14-09-04 |
Philips | ANUBIS-A | Hotel mode (de)activation for Anubis A with 3 loca | Hotel mode (de)activation for Anubis A with 3 local controls. Only for sets with 3 LOCAL CONTROLS
In service information HOTEL MODE for GR1AX / Anubis A&B / TV/VCR-1 4822 727 20384 a mistake is made for activation and de-activation of the Anubis A with 3 | 14-09-04 |
Philips | ANUBIS-A | How to activate "Hotel mode" | Applicable for family: 8 local controls Identification on uP: /R217
Hotel Mode activation: Select program 38, then press "INSTALL" on local keyboard and "SLEEPTIMER" on remote control for at least 4 seconds (at activation a green "H" is displayed (to re | 14-09-04 |
Philips | ANUBIS-A | Humm in stand-by. | Check SOPS transformer L5525 (4822 148 81121).
| 14-09-04 |