Make | Model | Problem | Solution | Date |
| | | |
Found: 4551
|
Philips | ANUBIS-A | Loss of VCR RF channel | Connect a zener diode BZX79-C6V2 (4822 130 34167) and a 1N4148 diode (4822 130 30621) in series (anode to anode) between pins 14 and 21 of 7015 (TDA4504).
The zener diode cathode is to be connected to pin 21.The 1N4148 cathode is to be connected to pin 1 | 14-09-04 |
Philips | ANUBIS-A | Missing of Hyper channels during search. | Two possible solutions:
1: Change C2017 into 33uF (4822 124 42058).
2: Change C2005 into 330nF (5322 121 42661).
REMARKS: Introduced in production for factory code:
Solution 1: PM069203, ZB079219 and higher
Solution 2: PM069207, ZB069212 and higher | 14-09-04 |
Philips | ANUBIS-A | No colour. | Track between pin 12 (IC7260) TDA4510 (4822 209 30389), C2252 (C2252; 4822 121 43526) and jumper R3306 (3k3; 4822 051 10332) interrupted. | 14-09-04 |
Philips | ANUBIS-A | No picture (CVBS SCART-out is OK) | Check IC7400 (TDA3653B/N1; 4822 209 60955) and R3449 (1 Ohm; 4822 052 10108) | 14-09-04 |
Philips | ANUBIS-A | No picture, no sound | In case of a dead set Anubis A, it is recommended to replace the the grey LOT by a black LOT:
4822 140 10406
The grey LOT which can cause this phenomena is used in sets produced from approx november 1993 onwards until week 9436 (so built-in in Anubis A | 14-09-04 |
Philips | ANUBIS-A | No picture, sound and OSD are O.K. | Check C2460 (33nF/100V).
| 14-09-04 |
Philips | ANUBIS-A | No picture, sound OK. | Check IC7280 (TDA3504/V2; 4822 209 32647).
| 14-09-04 |
Philips | ANUBIS-A | No reaction from RC5 remote control. Remote control O.K. | Check RC5 receiver LTM8848A-1P Pos.1685 (4822 218 20981).
| 14-09-04 |
Philips | ANUBIS-A | No sound. | Check/replace D6135 (LLZ-C4V7; 4822 130 80883).
| 14-09-04 |
Philips | ANUBIS-A | Noisy picture. | Resistance of 286 Ohm between pin 3-5 from SAW filter X1015 (OFWG 1961M); replace filter (4822 242 81388). | 14-09-04 |
|
Philips | ANUBIS-A | Only for ANUBIS-A AC. Adaption for service informa | Only for ANUBIS-A AC. Adaption for service information Anubis A/B 94.01 (4822 727 20292)
In the VCR identification electrical diagram the zener and the diode are exchanged: 6055 should be LL7-C6V2 (4822 130 81147), so zener symbol instead of diode symbo | 14-09-04 |
Philips | ANUBIS-A | Only noise in picture and ERROR 2. | Check/replace IC7702 (PCF84C81AP/098; 4822 209 31069). | 14-09-04 |
Philips | ANUBIS-A | Overshoot in RGB. | Change C2204, C2217 and C2230 into 270pF (4822 122 32142).
REMARKS: Introduced in production for factory code PM069148, ZB069203 and higher. | 14-09-04 |
Philips | ANUBIS-A | Picture and sound OK, but power supply hickups when set in standby. | This fault was found to be caused by transistor 7553 (BC858)
5322 130 42012. | 14-09-04 |
Philips | ANUBIS-A | Picture pulses when Remote Control handset used. H.T low at 92 volts | C2557 4N7 was found to read 20 kOhm. 4822 122 31784.
| 14-09-04 |
Philips | ANUBIS-A | Poor colors, PAL lines | Check/replace delay line IC7221 (TDA4660; 4822 209 63108).
| 14-09-04 |
Philips | ANUBIS-A | Poor colour sync | The following production changes have been introduced:
1) From week 9136 :
Capacitor C2267 (100nF) is changed to 150nF 4822 122 33812
and Capacitor C2268 (47nF) is changed to 22nF 4822 126 11544.
2) From week 9148 :
A 100nF capacitor 4822 122 | 14-09-04 |
Philips | ANUBIS-A | Poor tuning; unstable picture | Check/replace D6052 (1N4148 ; 4822 130 30621)- status diode.
Check/replace D6370 (LLZ-F12; 4822 130 82304).
REMARKS : The cure is applicable for poor tuning and for unstable picture, AFC hunting type fault, when a picture is present. | 14-09-04 |
Philips | ANUBIS-A | Programs lost after initial programming of replaced EEPROM | If after EEPROM replacement the programms stored in system FRANCE disappear after the switch-off, this is because the OSD showed system FRANCE but the microprocessor was in system EUROPE (due to a software bug)
The solution is to do after EEPROM replacem | 14-09-04 |
Philips | ANUBIS-A | Random E3 displayed at start-up | Change the following component:
Position: C2560 680uF into 1000uF 4822 124 40214
R3452 10R into 1R0 Safety 4822 052 10108
R3782 12R into 18R 4822 053 | 14-09-04 |
Philips | ANUBIS-A | Repeat repair after defective mains fuse 1500 | In case only the mains fuse 1500 (4822 070 32002) is replaced to repair an ANUBIS-A set, it is strongly recommended to replace the PTC 3501 (4822 116 40137) also.
Especially PTC's with printed weeknumber 317, 341, 346 and 406 can be damaged in case the f | 14-09-04 |
Philips | ANUBIS-A | Search does not stop; pin 12-IC7015 is ca. 2V. | When the search stopped the picture is out of synchronization,
Check/replace D6370 (LLZ-F12; 4822 130 82304). | 14-09-04 |
Philips | ANUBIS-A | Set "Motorboating" when in Standby. | Transistor 7553 was found to leaky B-E, type BC858A 5322 130 42012.
| 14-09-04 |
Philips | ANUBIS-A | Set is motorboating after 15 minutes. | Check C2545 (4u7/100V; 4822 124 40769).
| 14-09-04 |
Philips | ANUBIS-A | Set is motorboating after 15 minutes. | Check C2545 (4u7/100V; 4822 124 40769).
| 14-09-04 |
Philips | ANUBIS-A | Set shuts off sometimes. LEDs blinking. No output from pin 29 IC701 | Wire B42 from R3053 too C2354 was mounted too strong around tuner.
whith damaged isolation. | 14-09-04 |
Philips | ANUBIS-A | Set still defective after replacing SOPS repair kit | Check/replace thyristor 6570 (SFOR5D43; 4822 130 20245) and
D6569 (LL4148; 4822 130 80446).
REMARKS :SOPS repair kit is SBC7021; 4822 310 20491. | 14-09-04 |
Philips | ANUBIS-A | Sleep-timer timer skips 1 minute every 10 minutes. | Replace item 7600 with new software TMP47C834N-R165; 4822 900 10508.
REMARKS : Introduced in production in week 9413 or 9420 depending on the version | 14-09-04 |
Philips | ANUBIS-A | Sometimes "TXT - ERROR" | Replace X-tal X1710.
| 14-09-04 |
Philips | ANUBIS-A | Squeeking sound from CTV chassis. | Check/replace LOT L5445 (4822 140 10406).
Check for short circuit between coil 7 and 4 of LOT. | 14-09-04 |