Philips | FL2.16 | Blank picture. OSD not synchronised and too large, no TXT. | Check/replace memory IC 7900 (ST24C08CB1; 4822 209 32283).
| 14-09-04 |
Philips | FL2.16 | Blue picture, menu and TXT are OK. | Check IC7207 (SDA9205-2) LFR box (4822 209 31056).
| 14-09-04 |
Philips | FL2.16 | Both languages can be heard by Dual Nicam signals | For FL1-PTV change the software into V89; 4822 900 10732
For all other FL sets change the software into V88; 4822 900 10723
REMARKS :Introduced in production from week 9614 onwards. | 14-09-04 |
Philips | FL2.16 | BUX85F in mikroSOPS defective | Change the value of C2260 to 4n7F, replace 7270 with transistor
BD825 (4822 130 41746).
| 14-09-04 |
Philips | FL2.16 | Colored picture or picture is green/red, fly-back lines | Check zenerdiode 6450 on pin 19-IC7430 on the LSP. New diode must
be Philips (Telefunken does not work), 4822 130 81512
| 14-09-04 |
Philips | FL2.16 | Coloured spot on screen during switch-off | Replace R3037 by 1k3 (4822 051 10132).
REMARKS :
Introduced in production from week 9334 onwards.
| 14-09-04 |
Philips | FL2.16 | Colours not OK. No R-Y on test picture. | No R-Y on pin 1 TDA4650. C2385 (10NF; 4822 122 32442) is leaking.
| 14-09-04 |
Philips | FL2.16 | Correction | Correction
----------
All diagrams/partslists of the LFR box show on position 7244 an
Integrated Circuit with typenumber N74F74D.
However on this position an IC with typenumber N74F125D is used.
The codenumber for the correct N74F125D is: 5322 209 61857
| 14-09-04 |
Philips | FL2.16 | Correction to Product Survey 1993-4 | Correction to Product Survey 1993-4
-----------------------------------
Due to the introduction of new software (V67) an extra option bit
in option code 4 has to be set. For the following sets 32 has to be
added to option code 4:
25PT910A/01/19
25PT912A/0 | 14-09-04 |
Philips | FL2.16 | Correction to Product Survey 1996-4 | Correction to Product Survey 1996-4 (4822 727 21505)
----------------------------------------------------
On page PCS 41989 is mentioned at:
FL1.10 AG11 and higher: Control panel 4822 212 31708
FL1.17 AG20 : Control panel 4822 212 31708
FL | 14-09-04 |
|
Philips | FL2.16 | Correction to service information FL 95.01 | Correction to service information FL 95.01
------------------------------------------
Correction in the overview of 100Hz and Proscan boxen.
The replacement for service code 4822 212 30534 must be 4822 212 31231
The replacement for service code 4822 21 | 14-09-04 |
Philips | FL2.16 | Correction to service information FL 95.01 | Correction to service information FL 95.01
------------------------------------------
Correction in the overview of 100Hz and Proscan boxen.
The replacement for service code 4822 212 30534 must be 4822 212 31231
The replacement for service code 4822 21 | 14-09-04 |
Philips | FL2.16 | Correction to Service Manual | Correction to Service Manual
----------------------------
In service manual FL1/2.14, FL1/2.16, FL1.17 AA the code number of
the Scavem amplifier panel is wrong. The correct code number for
this panel is 4822 212 31469.
REMARKS :
The code number | 14-09-04 |
Philips | FL2.16 | Correction to service manual FLx.14/16/17 | Correction to service manual FLx.14/16/17 and FLx.24/26/27.
-----------------------------------------------------------
The code number of position 1200 (fuse 3,15 A) is wrong.
The correct code number is 4822 070 33152. This fuse is situated on
the LSP i | 14-09-04 |
Philips | FL2.16 | Correction to the Service Manual | Correction to the Service Manual
--------------------------------
In circuit diagram B on page 7 of the service manual
FL1.14/FL2.14/FL1.16/FL2.16 and FL 1.17 the resistors 3624 and 3625
are not drawn.
These resistors should be drawn on the position of 96 | 14-09-04 |
Philips | FL2.16 | Crazy behaviour: No response from RC or controls. | Other phenomenas: volume up/down, spontanuous service mode etc.
etc. in areas with TOP-teletext.
Replace control software by replacing EPROM IC7002 to version V82
(4822 900 10423). For easy mounting also the controlboard 7115
(on SSP) can be replaced by | 14-09-04 |
Philips | FL2.16 | Crazy behaviour: No response from RC or controls. | Other phenomenas: volume up/down, spontanuous service mode etc.
etc. in areas with TOP-teletext.
Replace control software by replacing EPROM IC7002 to version V83
(4822 900 10506). For easy mounting also the controlboard 7115
(on SSP) can be replaced by | 14-09-04 |
Philips | FL2.16 | Dark and bad synchronised picture, no colour. | Check power supply voltages to LFR box (+13; +5). If too high or
too low check IC7551 on LSP (LM358N; 4822 209 70672).
| 14-09-04 |
Philips | FL2.16 | Dark and bad synchronised picture, no colour. | Check power supply voltages to LFR box (+13; +5). If too high or
too low check IC7551 on LSP (LM358N; 4822 209 70672).
| 14-09-04 |
Philips | FL2.16 | Dark fuzzy picture. OSD and menu not in focus. | +5V was 7.8V and +13V was 15.5V
IC7551 (LM358N; 4822 209 70672) defective.
| 14-09-04 |
Philips | FL2.16 | Dark picture, only green led, no menu or OSD. | +5V supply was 4,1V. Voltage D6551 was 4,3V instead of 5,6V.
Check/replace D6551 (4822 130 80954).
| 14-09-04 |
Philips | FL2.16 | Distorted East-West & jitter on vertical side lines at switch-on. | Replace position C2611 on the large signal panel by a 1 uF
capacitor: 4822 121 51319.
REMARKS :
The East-west distortion shows a barrel-shape.
The jittering only occurs at the centre of vertical lines at the
left- and right-hand side.
After warm | 14-09-04 |
Philips | FL2.16 | Distorted East-West & jitter on vertical side lines at switch-on. | In the FL1.16 and FL2.16:
Replace position T7610 on the LSP by BD536FI (4822 130 63508).
Delete position 2615.
Replace position 2611 on the LSP by 2,2 uF (4822 124 41576).
Replace position 3608 on the LSP by 1k (4822 051 10102).
In the FL2.24:
Replace po | 14-09-04 |
Philips | FL2.16 | Distortion in vertical lines. | Rimple on micro sops? Check elco C2261 (100uF/50V; 4822 124 40255).
| 14-09-04 |
Philips | FL2.16 | East/West failure in cold condition. | Replace C2611 by 1uF (4822 121 51319) on LSP.
REMARKS :
Introduced in production in week 9332.
| 14-09-04 |
Philips | FL2.16 | Error 13 in memory. | Replace IC7120 on the digital scan box by new software version
P83C652 FFP/050; 4822 209 33289).
| 14-09-04 |
Philips | FL2.16 | Error code (99) after 10 sec. | IC7551 +5/+13V supply defective. (LM358; 4822 209 70672).
| 14-09-04 |
Philips | FL2.16 | Faulty horizontal sync. (intermittent and temperature-sensitive) | Capacitor 2117 10nF on LFR box mechanically damaged.
(4822 122 32422)
| 14-09-04 |
Philips | FL2.16 | Faulty horizontal sync. (intermittent and temperature-sensitive) | Capacitor 2117 10nF on LFR box mechanically damaged.
(4822 122 32422)
| 14-09-04 |
Philips | FL2.16 | Flyback lines in upperside of the picture. | Check IC7450 (TDA3654Q; 4822 209 73308).
| 14-09-04 |