Philips | Anubis A | no sound, vision or leds - short squeak at switch on | HT =100v - no line drive or 5v from psu lopt faulty | 14-09-04 |
Philips | Anubis A | NO TEXT , "E14" ON DISPLAY | XTAL 1701 ON SAA5246 | 14-09-04 |
Philips | Anubis A | Set works but if a bright sceen pic flickers & H.T | T7554 ( BC337 ) | 14-09-04 |
Philips | Anubis A | Sound no pic field collapse | TDA3653 field chip dry jointed but resoldering did not cure - replacement did | 14-09-04 |
Philips | Anubis A | WHEN IN STBY LED FLASHES AND LOUDSPEAKER THUMPS | D6568 6v2 ZENER | 14-09-04 |
Philips | Anubis A | Dead but blows fuse after repair kit fitted | Crack in print between pin 12 of chopper tfmr & optocoupler | 14-09-04 |
Philips | Anubis A 14PT155A/05 | Dead - 95V being dragged down because the line dr tr turned hard on by 12V from pin 29 of IC7015 (TDA4504B). | LOPTx | 14-09-04 |
Philips | Anubis A 52ZY3535 | To exit Demo Mode | Press Prog - & + together at sw on | 14-09-04 |
Philips | Anubis A AC | Blows BUT11A lop tr int | Dry joints scan coils conn plug | 14-09-04 |
Philips | Anubis A AC | Dead | C2450 scan coupling cap s/c 330nF in 17/17" CRTs | 14-09-04 |
|
Philips | Anubis A AC | Narrow pic 4" wide - rest blanked out | TDA3504 vid contr chip IC7280 | 14-09-04 |
Philips | Anubis A-AC | Flickers on high brightness with drop in HT | Tr7554 BC337A leaky | 14-09-04 |
Philips | Anubis A-AC | Ok until put into st/by when LED flashes with thumping noise | D6568 LLZF6V2 leaky in st/by cct | 14-09-04 |
Philips | Anubis A-AC 17PT166A | Dead - in shutdown mode | s/c across LOPTr coll & emitt - not LOPTx this time but C2450 330nF 250v scan coupling cap s/c | 14-09-04 |
Philips | Anubis A.AB | "E3" showing at bottom of screen | Cured by replacing EEPROM with a blank | 14-09-04 |
Philips | Anubis A.AB | Tuning - not stopping when tuning or memorise | Ident pin on micro going leaky - req new micro | 14-09-04 |
Philips | Anubis A.AC | Blank raster - no sound ,OSD OK | Stuck in AV mode. Pin 18 IC7015 read 3v istead of 0v as Tr7877 never soldered | 14-09-04 |
Philips | Anubis B | ER4 displayed on screen - no text only lines. | 27Mhz Crystal 1701. | 14-09-04 |
Philips | Anubis B | HORIZONTAL GREY LINE ON SCREEN | C2413 10nF IN FIELD CCT | 14-09-04 |
Philips | Anubis B | IF IC7685 REPLACED SET WILL DISPLAY NORWEGIAN AND | MENU SET "BARNLAS" TO "FRAN" ( OFF ) THEN SET MAY BE RESET | 14-09-04 |
Philips | Anubis B | No E-W corr | R3404 47R in module 110 panel o/c | 14-09-04 |
Philips | Anubis B | no txt | 27Mhx xtal | 14-09-04 |
Philips | Anubis B | WORKS BUT LED FLASHES AND E4 ON SCREEN + NO TEXT | 27mhz XTAL ON TEXT PCB | 14-09-04 |
Philips | Anubis B AA | Dead - chopper tr s/c | Replaced opto IC7514 CNR50, Control chip IC7500 & chopper tr | 14-09-04 |
Philips | Anubis B-AA | Hor grey line over pic | Field scan has osc on it - C4213 10nF o/c | 14-09-04 |
Philips | Anubis B-AA | LED flashing with "ER4" displayed | Fault in Txt - lines only in Txt - Xtal 1701 27Mhz faulty | 14-09-04 |
Philips | Anubis B-AA | Removing "Demo" mode | Switch on whilst holding in "VOL-" & "Prog+" in together. | 14-09-04 |
Philips | Anubis B-AA | When replacing EEPROM IC7685 ST24C02P | Default language is Norwegian! & childlock (Barnlas)active. To clear childlock select spec functs option C on main menu. Next menu - Barnlas as option A - set to Fran (off). Then able to set up other parameters | 14-09-04 |
Philips | Anubis BAA | Dead with pulsing squeak | C2540 2200µ 16v leaky | 14-09-04 |
Philips | ANUBIS-A | + 95V is too low. | Check/replace TS7445 (BUT11AF;4822 130 42679).
| 14-09-04 |